Example 3

System solutions >Extensive roof planting
Pressure-resistant drainage with Bauder DSE 20 drainage and storage element - continuous drainage under planting and paving slabs.

(kopie 1)

1Plantinglow-growing perennials,
seed mixture
2Vegetation layerBauder extensive substrate
3Filter layerBauder FV 125 filter fleece
4Water storage / drainage layerBauder DSE 20 drainage and storage panel
5Protective layerBauder FSM 600 protection mat
6Separating and sliding layerBauder PE 02 separating foil

Technical data:

Roof pitch1 - 5°
Thickness10.0 cm
Water storage capacity41.4 l/m2
Total weight, saturated121.1 kg/m2